Please use this identifier to cite or link to this item:
https://hdl.handle.net/1959.11/10161
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Schneider, Derek | en |
dc.contributor.author | Lamb, David | en |
dc.contributor.author | Trotter, Mark | en |
local.source.editor | Editor(s): MG Trotter, EB Garraway and DW Lamb | en |
dc.date.accessioned | 2012-05-16T15:09:00Z | - |
dc.date.issued | 2009 | - |
dc.identifier.citation | Proceedings of the 13th Annual Symposium on Precision Agriculture in Australasia, p. 98-98 | en |
dc.identifier.isbn | 9781921597114 | en |
dc.identifier.uri | https://hdl.handle.net/1959.11/10161 | - |
dc.description.abstract | Multi-temporal electromagnetic induction (EMI e.g. EM38) surveys of fields may provide a greater insight into soil water dynamics, and when deployed as such may better inform irrigation or fertiliser management with a view to improving water use efficiency. Measuring absolute soil moisture content and subsequent changes over time requires detection of apparent electrical conductivity (ECa) changes as small as a few mS/m, and this requires an accuracy in instrument calibration and performance that is not achievable by relying solely on 'standard' instrument nulling and calibration procedures. In-field calibration has been reported by other workers as a major factor resulting in high levels of divergence from theoretically modelled responses especially at low conductivity ranges and significant instrument drifts have also been observed in this present work. To this end, a simple and inexpensive calibration rig and procedure has been developed to monitor the gain and offset of EM38 sensors in response to a constant q-coil at the beginning and end of each survey. The 'response curve' can be used to derive instrument-specific temperature correction algorithms (assuming the case temperature is monitored and logged during subsequent surveys) and also be used as the basis of a conversion algorithm to correct multi-temporal survey data to a common instrument performance characteristic. | en |
dc.language | en | en |
dc.publisher | University of New England, Precision Agriculture Research Group | en |
dc.relation.ispartof | Proceedings of the 13th Annual Symposium on Precision Agriculture in Australasia | en |
dc.title | A simple field calibration procedure for EM38 units when undertaking multi-temporal surveys | en |
dc.type | Conference Publication | en |
dc.relation.conference | Precision Agriculture 2009: 13th Annual Symposium on Precision Agriculture in Australasia | en |
dc.subject.keywords | Agricultural Spatial Analysis and Modelling | en |
local.contributor.firstname | Derek | en |
local.contributor.firstname | David | en |
local.contributor.firstname | Mark | en |
local.subject.for2008 | 070104 Agricultural Spatial Analysis and Modelling | en |
local.subject.seo2008 | 829999 Plant Production and Plant Primary Products not elsewhere classified | en |
local.profile.school | School of Science and Technology | en |
local.profile.school | Office of Faculty of Science, Agriculture, Business and Law | en |
local.profile.school | School of Environmental and Rural Science | en |
local.profile.email | dschnei5@une.edu.au | en |
local.profile.email | dlamb@une.edu.au | en |
local.profile.email | mtrotte3@une.edu.au | en |
local.output.category | E3 | en |
local.record.place | au | en |
local.record.institution | University of New England | en |
local.identifier.epublicationsrecord | une-20120516-075320 | en |
local.date.conference | 10th - 11th September, 2009 | en |
local.conference.place | Armidale, Australia | en |
local.publisher.place | Armidale, Australia | en |
local.format.startpage | 98 | en |
local.format.endpage | 98 | en |
local.contributor.lastname | Schneider | en |
local.contributor.lastname | Lamb | en |
local.contributor.lastname | Trotter | en |
dc.identifier.staff | une-id:dschnei5 | en |
dc.identifier.staff | une-id:dlamb | en |
dc.identifier.staff | une-id:mtrotte3 | en |
local.profile.orcid | 0000-0002-1897-4175 | en |
local.profile.role | author | en |
local.profile.role | author | en |
local.profile.role | author | en |
local.identifier.unepublicationid | une:10354 | en |
dc.identifier.academiclevel | Academic | en |
dc.identifier.academiclevel | Academic | en |
dc.identifier.academiclevel | Academic | en |
local.title.maintitle | A simple field calibration procedure for EM38 units when undertaking multi-temporal surveys | en |
local.output.categorydescription | E3 Extract of Scholarly Conference Publication | en |
local.relation.url | http://www.une.edu.au/parg/documents/proceedings.pdf | en |
local.conference.details | Precision Agriculture 2009: 13th Annual Symposium on Precision Agriculture in Australasia, Armidale, Australia, 10th - 11th September, 2009 | en |
local.search.author | Schneider, Derek | en |
local.search.author | Lamb, David | en |
local.search.author | Trotter, Mark | en |
local.uneassociation | Unknown | en |
local.year.published | 2009 | en |
local.date.start | 2009-09-10 | - |
local.date.end | 2009-09-11 | - |
Appears in Collections: | Conference Publication School of Environmental and Rural Science School of Science and Technology |
Files in This Item:
File | Description | Size | Format |
---|
Page view(s)
1,118
checked on Mar 7, 2023
Items in Research UNE are protected by copyright, with all rights reserved, unless otherwise indicated.