Please use this identifier to cite or link to this item: https://hdl.handle.net/1959.11/7304
Title: EM38 for volumetric soil water content estimation in the root-zone of deep vertosol soils
Contributor(s): Hossain, Bilal (author); Lamb, David  (author); Lockwood, Peter  (author); Frazier, Paul  (author)
Publication Date: 2010
DOI: 10.1016/j.compag.2010.07.003
Handle Link: https://hdl.handle.net/1959.11/7304
Abstract: Electromagnetic induction sensors, such as EM38, are used widely for monitoring and mapping soil attributes via the apparent electrical conductivity (ECa) of the soil. The sensor response is the depth-integrated combination of the depth-response function of the EM38 and 'local' electrical conductivity (ECaz) at depth. In deep, Vertosol soils, assuming the instrument depth-response function is not perturbed by the soil and where volumetric moisture content at depth (θv(z)) dominates ECaz, EM38 should be capable of predicting average moisture content without recourse to mathematically complicated, and unstable profile inversion processes. Firstly a multi-height EM38 experiment was conducted over deep Vertosol soils to confirm the veracity of the EM38 depth-response function and test the concomitant hypothesis of the EM38 response being an integrated (i.e. additive) combination of depth-response function and θv(z). Secondly, depth profiles of moisture content were used to calibrate the EM38 to infer average θv(z) within the 'root-zone of crop plants - here taken to be surface - 0.8 m and surface - 1.2 m. EM38 calibration was performed using soil samples acquired from both extracted cores and excavated pits. Mathematical summation of measured θv(z) from sectioned cores and the known depth-response function of the EM38 was found to explain 99% and 97% of the variance in measured ECa for horizontal and vertical dipole configurations at multiple sensor heights above the ground. Average θv from surface to 0.8 m (θ0.8) and surface to 1.2 m (θ1.2) explained only 37% and 46% of the variance in on-ground ECa for vertical dipole configuration measurements compared to 55% and 56% of the variance for horizontal dipole configuration. In a separate validation experiment, the shape of the vertical moisture profile proved highly influential in determining the ability of the calibration equations to infer underlying average moisture content, especially where the depth profile shapes differed between sensor calibration and subsequent field validation (for example following rainfall or irrigation).
Publication Type: Journal Article
Source of Publication: Computers and Electronics in Agriculture, 74(1), p. 100-109
Publisher: Elsevier BV
Place of Publication: Netherlands
ISSN: 1872-7107
0168-1699
Fields of Research (FoR) 2008: 070101 Agricultural Land Management
Socio-Economic Objective (SEO) 2008: 820301 Cotton
820507 Wheat
820502 Canola
Peer Reviewed: Yes
HERDC Category Description: C1 Refereed Article in a Scholarly Journal
Appears in Collections:Journal Article

Files in This Item:
3 files
File Description SizeFormat 
Show full item record
Google Media

Google ScholarTM

Check

Altmetric


Items in Research UNE are protected by copyright, with all rights reserved, unless otherwise indicated.