Title: Micro-CT and Histological Evaluation of an Neural Interface Implanted Within a Blood Vessel
Contributor(s): Opie, Nicholas Lachlan (author); Nagel, Nicole R van der (author); John, Sam E (author); Vessey, Kirstan A  (author)orcid ; Rind, Gil S (author); Ronayne, Stephen M (author); Fletcher, Erica L (author); May, Clive N (author); O'Brien, Terence J (author); Oxley, Thomas J (author)
Publication Date: 2017
DOI: 10.1109/tbme.2016.2552226
Handle Link: https://hdl.handle.net/1959.11/59040
Abstract: 

—Objective: Recently, we reported the development of a stent-mounted electrode array (Stentrode) capable of chronically recording neural signals from within a blood vessel with high fidelity. Preliminary data suggested incorporation of the Stentrode into the blood vessel wall was associated with improved recording sensitivity. We now investigate neointimal incorporation of the Stentrode, implanted in a cohort of sheep for up to 190 days. Methods: MicroCT, obtained from the Imaging and Medical Beamline at the Australian Synchrotron, and histomorphometic techniques developed specifically for evaluation of cerebral vasculature implanted with a stent-electrode array were compared as measures to assess device incorporation and vessel patency. Results: Both micro-CT analysis and histomorphometry, revealed a strong correlation between implant duration and the number of incorporated stent struts. <10% (26/268) of stent struts were covered in neointima in sheep implanted for <2 weeks, increasing to >78% (191/243) between 2 and 4 weeks. Average strut-to-lumen thickness from animals implanted >12 weeks was comparable across both modalities, 339 ± 15 µm measured using micro-CT and 331 ± 19 µm (n = 292) measured histologically. There was a strong correlation between lumen areas measured using the two modalities (p < 0.001), with no observation of vessel occlusion observed from any of the 12 animals implanted for up to 190 days. Conclusion: Micro-CT and the histomorphome tric techniques we developed are comparable and can both be used to identify incorporation of a Stentrode implanted in cerebral vessels. Significance: This study demonstrates preliminary safety of a stent-electrode array implanted in cerebral vasculature, which may facilitate technological advances in minimally invasive brain–computer interfaces.

Publication Type: Journal Article
Source of Publication: IEEE transactions on bio-medical engineering, 64(4), p. 928-934
Publisher: Institute of Electrical and Electronics Engineers
Place of Publication: United States of America
ISSN: 1558-2531
0018-9294
Fields of Research (FoR) 2020: 320907 Sensory systems
321204 Vision science
Socio-Economic Objective (SEO) 2020: 280103 Expanding knowledge in the biomedical and clinical sciences
Peer Reviewed: Yes
HERDC Category Description: C1 Refereed Article in a Scholarly Journal
Appears in Collections:Journal Article
School of Science and Technology

Files in This Item:
1 files
File SizeFormat 
Show full item record

SCOPUSTM   
Citations

33
checked on Dec 7, 2024
Google Media

Google ScholarTM

Check

Altmetric


Items in Research UNE are protected by copyright, with all rights reserved, unless otherwise indicated.