Please use this identifier to cite or link to this item:
https://hdl.handle.net/1959.11/7496
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Moens, Pierre | en |
dc.contributor.author | Gratton, Enrico | en |
dc.contributor.author | Salvemini, Iyrri | en |
dc.date.accessioned | 2011-05-20T10:34:00Z | - |
dc.date.issued | 2011 | - |
dc.identifier.citation | Microscopy Research and Technique, 74(4), p. 377-388 | en |
dc.identifier.issn | 1097-0029 | en |
dc.identifier.issn | 1059-910X | en |
dc.identifier.uri | https://hdl.handle.net/1959.11/7496 | - |
dc.description.abstract | Fluorescence correlation spectroscopy (FCS) was developed in 1972 by Magde, Elson and Webb. Photon counting detectors and avalanche photodiodes have become standards in FCS to the point that there is a widespread belief that these detectors are essential to perform FCS experiments, despite the fact that FCS was developed using analog detectors. Spatial and temporal intensity fluctuation correlations using analog detection on a commercial Olympus Fluoview 300 microscope have been reported by Brown et al. (2008). However, each analog instrument has its own idiosyncrasies that need to be understood before using the instrument for FCS. In this work, we explore the capabilities of the Nikon C1, a low-cost confocal microscope, to obtain single point FCS, Raster-scan image correlation spectroscopy (RICS), and Number and Brightness data both in solution and incorporated into the membrane of giant unilamellar vesicles. We show that it is possible to obtain dynamic information about fluorescent molecules from single point FCS, RICS, and Number and Brightness using the Nikon C1. We highlighted the fact that care should be taken in selecting the acquisition parameters to avoid possible artifacts due to the detector noise. However, due to relatively large errors in determining the distribution of digital levels for a given microscope setting, the system is probably only adequate for determining relative brightness within the same image. | en |
dc.language | en | en |
dc.publisher | John Wiley & Sons, Inc | en |
dc.relation.ispartof | Microscopy Research and Technique | en |
dc.title | Fluorescence Correlation Spectroscopy, Raster Image Correlation Spectroscopy, and Number and Brightness on a Commercial Confocal Laser Scanning Microscope with Analog Detectors (Nikon C1) | en |
dc.type | Journal Article | en |
dc.identifier.doi | 10.1002/jemt.20919 | en |
dcterms.accessRights | Green | en |
dc.subject.keywords | Biological Physics | en |
local.contributor.firstname | Pierre | en |
local.contributor.firstname | Enrico | en |
local.contributor.firstname | Iyrri | en |
local.subject.for2008 | 029901 Biological Physics | en |
local.subject.seo2008 | 920102 Cancer and Related Disorders | en |
local.profile.school | School of Science and Technology | en |
local.profile.school | Human Biology and Physiology | en |
local.profile.email | pmoens@une.edu.au | en |
local.profile.email | egratton22@yahoo.com | en |
local.profile.email | isalvem2@une.edu.au | en |
local.output.category | C1 | en |
local.record.place | au | en |
local.record.institution | University of New England | en |
local.identifier.epublicationsrecord | une-20110223-12087 | en |
local.publisher.place | United States of America | en |
local.format.startpage | 377 | en |
local.format.endpage | 388 | en |
local.identifier.scopusid | 84893442576 | en |
local.url.open | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3001136 | en |
local.peerreviewed | Yes | en |
local.identifier.volume | 74 | en |
local.identifier.issue | 4 | en |
local.access.fulltext | Yes | en |
local.contributor.lastname | Moens | en |
local.contributor.lastname | Gratton | en |
local.contributor.lastname | Salvemini | en |
dc.identifier.staff | une-id:pmoens | en |
dc.identifier.staff | une-id:isalvem2 | en |
local.profile.orcid | 0000-0003-3121-5306 | en |
local.profile.role | author | en |
local.profile.role | author | en |
local.profile.role | author | en |
local.identifier.unepublicationid | une:7664 | en |
dc.identifier.academiclevel | Academic | en |
dc.identifier.academiclevel | Academic | en |
local.title.maintitle | Fluorescence Correlation Spectroscopy, Raster Image Correlation Spectroscopy, and Number and Brightness on a Commercial Confocal Laser Scanning Microscope with Analog Detectors (Nikon C1) | en |
local.output.categorydescription | C1 Refereed Article in a Scholarly Journal | en |
local.relation.grantdescription | NHMRC/568301 | en |
local.search.author | Moens, Pierre | en |
local.search.author | Gratton, Enrico | en |
local.search.author | Salvemini, Iyrri | en |
local.uneassociation | Unknown | en |
local.identifier.wosid | 000288859800012 | en |
local.year.published | 2011 | en |
Appears in Collections: | Journal Article |
Files in This Item:
File | Description | Size | Format |
---|
SCOPUSTM
Citations
19
checked on Jun 8, 2024
Page view(s)
1,312
checked on Feb 25, 2024
Items in Research UNE are protected by copyright, with all rights reserved, unless otherwise indicated.