Please use this identifier to cite or link to this item:
https://hdl.handle.net/1959.11/17661
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Davies, Justin Bryan | en |
dc.contributor.author | Bosi, Stephen G | en |
dc.contributor.author | Baldock, C | en |
dc.date.accessioned | 2015-07-15T17:44:00Z | - |
dc.date.issued | 2010 | - |
dc.identifier.citation | Journal of Physics: Conference Series, 250(1), p. 1-5 | en |
dc.identifier.issn | 1742-6596 | en |
dc.identifier.issn | 1742-6588 | en |
dc.identifier.uri | https://hdl.handle.net/1959.11/17661 | - |
dc.description.abstract | Genipin cross links gelatin to slowly form a blue colour that bleaches upon irradiation. Spectrophotometric measurements of the absorbance change following irradiation to doses up to 100 Gy gives a linear dose response for certain concentrations of the gel ingredients; genipin, gelatin and sulphuric acid. Dose sensitivity increases with increasing concentrations of sulphuric acid and genipin and is also strongly dependent on the time allowed for the genipin-gelatin cross linking reaction (referred to here as blending) to take place. The optimum formulation of this gel was found for genipin concentration between 0.3 - 0.5 mM and blending time of at least 4 h. | en |
dc.language | en | en |
dc.publisher | Institute of Physics Publishing Ltd | en |
dc.relation.ispartof | Journal of Physics: Conference Series | en |
dc.title | The characterisation of a genipin-gelatin gel dosimeter | en |
dc.type | Journal Article | en |
dc.identifier.doi | 10.1088/1742-6596/250/1/012008 | en |
dc.subject.keywords | Medical Physics | en |
local.contributor.firstname | Justin Bryan | en |
local.contributor.firstname | Stephen G | en |
local.contributor.firstname | C | en |
local.subject.for2008 | 029903 Medical Physics | en |
local.subject.seo2008 | 929999 Health not elsewhere classified | en |
local.profile.school | School of Science and Technology | en |
local.profile.email | jbd@ansto.gov.au | en |
local.profile.email | sbosi@une.edu.au | en |
local.output.category | C1 | en |
local.record.place | au | en |
local.record.institution | University of New England | en |
local.identifier.epublicationsrecord | une-20150701-164214 | en |
local.publisher.place | United Kingdom | en |
local.identifier.runningnumber | 012008 | en |
local.format.startpage | 1 | en |
local.format.endpage | 5 | en |
local.identifier.scopusid | 78650536915 | en |
local.peerreviewed | Yes | en |
local.identifier.volume | 250 | en |
local.identifier.issue | 1 | en |
local.contributor.lastname | Davies | en |
local.contributor.lastname | Bosi | en |
local.contributor.lastname | Baldock | en |
dc.identifier.staff | une-id:sbosi | en |
local.profile.role | author | en |
local.profile.role | author | en |
local.profile.role | author | en |
local.identifier.unepublicationid | une:17875 | en |
local.identifier.handle | https://hdl.handle.net/1959.11/17661 | en |
dc.identifier.academiclevel | Academic | en |
dc.identifier.academiclevel | Academic | en |
local.title.maintitle | The characterisation of a genipin-gelatin gel dosimeter | en |
local.output.categorydescription | C1 Refereed Article in a Scholarly Journal | en |
local.search.author | Davies, Justin Bryan | en |
local.search.author | Bosi, Stephen G | en |
local.search.author | Baldock, C | en |
local.uneassociation | Unknown | en |
local.year.published | 2010 | en |
Appears in Collections: | Journal Article |
Files in This Item:
File | Description | Size | Format |
---|
SCOPUSTM
Citations
7
checked on Nov 9, 2024
Page view(s)
920
checked on Mar 9, 2023
Items in Research UNE are protected by copyright, with all rights reserved, unless otherwise indicated.