Please use this identifier to cite or link to this item: https://hdl.handle.net/1959.11/17658
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGorjiara, Tinaen
dc.contributor.authorHill, Robinen
dc.contributor.authorKuncic, Zdenkaen
dc.contributor.authorBosi, Stephen Gen
dc.contributor.authorBaldock, Cliveen
dc.date.accessioned2015-07-15T17:09:00Z-
dc.date.issued2010-
dc.identifier.citationJournal of Physics: Conference Series, 250(1), p. 1-5en
dc.identifier.issn1742-6596en
dc.identifier.issn1742-6588en
dc.identifier.urihttps://hdl.handle.net/1959.11/17658-
dc.description.abstractGenipin gel is a radiochromic gel with the potential to be used as a three dimensional (3D) dosimeter. An ideal dosimeter should present radiologically water equivalent properties. In this work, we have evaluated the water equivalency of genipin gel by calculating its radiological properties, such as mass and electron density, effective atomic number, fractional interaction probabilities, mass energy absorption coefficient and mass stopping powers as well as depth doses for kilovoltage x-ray and megavoltage electron beams. Based on the results of this study, we conclude that genipin gel is a water equivalent dosimeter.en
dc.languageenen
dc.publisherInstitute of Physics Publishing Ltden
dc.relation.ispartofJournal of Physics: Conference Seriesen
dc.titleAn evaluation of Genipin gel as a water equivalent dosimeter for megavoltage electron beams and kilovoltage x-ray beamsen
dc.typeJournal Articleen
dc.identifier.doi10.1088/1742-6596/250/1/012036en
dc.subject.keywordsMedical Physicsen
local.contributor.firstnameTinaen
local.contributor.firstnameRobinen
local.contributor.firstnameZdenkaen
local.contributor.firstnameStephen Gen
local.contributor.firstnameCliveen
local.subject.for2008029903 Medical Physicsen
local.subject.seo2008929999 Health not elsewhere classifieden
local.profile.schoolSchool of Science and Technologyen
local.profile.emailtina@gorjiara.comen
local.profile.emailrobin.hill@email.cs.nsw.gov.auen
local.profile.emailzdenka.kuncic@sydney.edu.auen
local.profile.emailsbosi@une.edu.auen
local.profile.emailclive.baldock@gmail.comen
local.output.categoryC1en
local.record.placeauen
local.record.institutionUniversity of New Englanden
local.identifier.epublicationsrecordune-20150701-181433en
local.publisher.placeUnited Kingdomen
local.identifier.runningnumber0120036en
local.format.startpage1en
local.format.endpage5en
local.identifier.scopusid78650556957en
local.peerreviewedYesen
local.identifier.volume250en
local.identifier.issue1en
local.contributor.lastnameGorjiaraen
local.contributor.lastnameHillen
local.contributor.lastnameKuncicen
local.contributor.lastnameBosien
local.contributor.lastnameBaldocken
dc.identifier.staffune-id:sbosien
local.profile.roleauthoren
local.profile.roleauthoren
local.profile.roleauthoren
local.profile.roleauthoren
local.profile.roleauthoren
local.identifier.unepublicationidune:17872en
local.identifier.handlehttps://hdl.handle.net/1959.11/17658en
dc.identifier.academiclevelAcademicen
dc.identifier.academiclevelAcademicen
local.title.maintitleAn evaluation of Genipin gel as a water equivalent dosimeter for megavoltage electron beams and kilovoltage x-ray beamsen
local.output.categorydescriptionC1 Refereed Article in a Scholarly Journalen
local.search.authorGorjiara, Tinaen
local.search.authorHill, Robinen
local.search.authorKuncic, Zdenkaen
local.search.authorBosi, Stephen Gen
local.search.authorBaldock, Cliveen
local.uneassociationUnknownen
local.year.published2010en
Appears in Collections:Journal Article
Files in This Item:
3 files
File Description SizeFormat 
Show simple item record

SCOPUSTM   
Citations

9
checked on Nov 9, 2024

Page view(s)

930
checked on Mar 8, 2023
Google Media

Google ScholarTM

Check

Altmetric


Items in Research UNE are protected by copyright, with all rights reserved, unless otherwise indicated.