Please use this identifier to cite or link to this item: https://hdl.handle.net/1959.11/12173
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMahini, Seyed Saeeden
dc.contributor.authorRonagh, Hamid Ren
dc.date.accessioned2013-02-27T17:20:00Z-
dc.date.issued2011-
dc.identifier.citationComposite Structures, 93(10), p. 2460-2472en
dc.identifier.issn1879-1085en
dc.identifier.issn0263-8223en
dc.identifier.urihttps://hdl.handle.net/1959.11/12173-
dc.description.abstractIn an RC building subjected to lateral loads, the beam-column joints constitute one of the critical regions. In existing frames, which were not adequately designed, a practical way of controlling plastic hinging and implement the strong-column weak-beam concept is through the use of a web-bonded FRP retrofitting system. This paper presents the results of an experimental and numerical study carried out in order to evaluate the ability of CFRP sheets in preventing the plastic hinge formation at the face of the column in exterior RC joints. Seven scaled-down RC exterior joints of a typical Ordinary Moment Resisting Frame are tested under moderately monotonic/cyclic loads. Two specimens are used as control while the other five are CFRP-strengthened/repaired of different lengths and thicknesses. The results show that carbon fibre sheets can effectively relocate the plastic hinge away from the face of the column. Non-linear numerical results using ANSYS are also presented and discussed.en
dc.languageenen
dc.publisherElsevier Ltden
dc.relation.ispartofComposite Structuresen
dc.titleWeb-bonded FRPs for relocation of plastic hinges away from the column face in exterior RC jointsen
dc.typeJournal Articleen
dc.identifier.doi10.1016/j.compstruct.2011.04.002en
dc.subject.keywordsEarthquake Engineeringen
dc.subject.keywordsStructural Engineeringen
dc.subject.keywordsInfrastructure Engineering and Asset Managementen
local.contributor.firstnameSeyed Saeeden
local.contributor.firstnameHamid Ren
local.subject.for2008090504 Earthquake Engineeringen
local.subject.for2008090505 Infrastructure Engineering and Asset Managementen
local.subject.for2008090506 Structural Engineeringen
local.subject.seo2008870204 Residential Construction Designen
local.subject.seo2008870203 Industrial Construction Designen
local.subject.seo2008870299 Construction Design not elsewhere classifieden
local.profile.schoolSchool of Environmental and Rural Scienceen
local.profile.emailsmahini@une.edu.auen
local.profile.emailhronagh@uq.edu.auen
local.output.categoryC1en
local.record.placeauen
local.record.institutionUniversity of New Englanden
local.identifier.epublicationsrecordune-20130124-150521en
local.publisher.placeUnited Kingdomen
local.format.startpage2460en
local.format.endpage2472en
local.peerreviewedYesen
local.identifier.volume93en
local.identifier.issue10en
local.contributor.lastnameMahinien
local.contributor.lastnameRonaghen
dc.identifier.staffune-id:smahinien
local.profile.roleauthoren
local.profile.roleauthoren
local.identifier.unepublicationidune:12379en
dc.identifier.academiclevelAcademicen
local.title.maintitleWeb-bonded FRPs for relocation of plastic hinges away from the column face in exterior RC jointsen
local.relation.fundingsourcenote/IPRS/UQIPRSen
local.output.categorydescriptionC1 Refereed Article in a Scholarly Journalen
local.search.authorMahini, Seyed Saeeden
local.search.authorRonagh, Hamid Ren
local.uneassociationUnknownen
local.identifier.wosid000292787800003en
local.year.published2011en
Appears in Collections:Journal Article
Files in This Item:
2 files
File Description SizeFormat 
Show simple item record

SCOPUSTM   
Citations

81
checked on Mar 23, 2024

Page view(s)

1,098
checked on Mar 10, 2024
Google Media

Google ScholarTM

Check

Altmetric


Items in Research UNE are protected by copyright, with all rights reserved, unless otherwise indicated.