Please use this identifier to cite or link to this item: https://hdl.handle.net/1959.11/4144
Full metadata record
DC FieldValueLanguage
dc.contributor.authorFaulkner, Richard Daviden
local.source.editorEditor(s): Robert A Patterson and Malcolm J Jonesen
dc.date.accessioned2010-01-14T10:07:00Z-
dc.date.issued2005-
dc.identifier.citationProceedings of On-site '05: Performance Assessment for On-site Systems, p. 171-177en
dc.identifier.isbn0957943822en
dc.identifier.urihttps://hdl.handle.net/1959.11/4144-
dc.description.abstractThis paper describes trials carried out with a disinfection system developed by Packaged Environmental Solutions (F'ES). The trials were carried out at the Woolgoolga Sewage Treatment Plant, which is operated by the Coffs Harbour City Council, in New South Wales. The system uses a heat disinfection system with heat exchange and recovery to minimise operating costs. The disinfection system can handle from 200 L/h to 20,000 L/h, and the current tests were conducted at a rate of about 300 L/h at a temperature of 85 –90°C with a retention time of about two and a half minutes. The unit was positioned after secondary treatment (activated sludge) and filtering (disc filters) and results were also obtained following the standard disinfection by chlorine for comparison. Both faecal coliforms and total coliforms were measured, before and after disinfection. Results indicate that FDS is a viable alternative to conventional disinfection methods for reuse of treated effluent.en
dc.languageenen
dc.publisherLanfax Laboratoriesen
dc.relation.ispartofProceedings of On-site '05: Performance Assessment for On-site Systemsen
dc.titleChemical free disinfection using the fluid disinfection system (FDS)™en
dc.typeConference Publicationen
dc.relation.conferenceOn-site '05 Conference: Performance Assessment for On-site Systemsen
dc.subject.keywordsWater Quality Engineeringen
local.contributor.firstnameRichard Daviden
local.subject.for2008090508 Water Quality Engineeringen
local.subject.seo2008960903 Coastal and Estuarine Water Managementen
local.identifier.epublicationsvtls086333512en
local.profile.schoolSchool of Environmental and Rural Scienceen
local.profile.emailrfaulkne@une.edu.auen
local.output.categoryE1en
local.record.placeauen
local.record.institutionUniversity of New Englanden
local.identifier.epublicationsrecordpes:2394en
local.date.conference27th - 30th September, 2005en
local.conference.placeArmidale, Australiaen
local.publisher.placeArmidale, Australiaen
local.format.startpage171en
local.format.endpage177en
local.peerreviewedYesen
local.contributor.lastnameFaulkneren
dc.identifier.staffune-id:rfaulkneen
local.profile.roleauthoren
local.identifier.unepublicationidune:4244en
dc.identifier.academiclevelAcademicen
local.title.maintitleChemical free disinfection using the fluid disinfection system (FDS)™en
local.output.categorydescriptionE1 Refereed Scholarly Conference Publicationen
local.relation.urlhttp://trove.nla.gov.au/work/12861558?selectedversion=NBD27892677en
local.conference.detailsOn-site '05 Conference: Performance Assessment for On-site Systems, Armidale, Australia, 27th - 30th September, 2005en
local.search.authorFaulkner, Richard Daviden
local.uneassociationUnknownen
local.year.published2005en
local.date.start2005-09-27-
local.date.end2005-09-30-
Appears in Collections:Conference Publication
Files in This Item:
2 files
File Description SizeFormat 
Show simple item record

Page view(s)

1,148
checked on Apr 21, 2024

Download(s)

2
checked on Apr 21, 2024
Google Media

Google ScholarTM

Check


Items in Research UNE are protected by copyright, with all rights reserved, unless otherwise indicated.