Abstract: In the gravimetric calibration method of water meters, the volume of water that has passed through the equipment under test (EUT) is generally collected into a tank and the quantity (mass) determined by weighing. The mass of water collected is then converted into a volume. This conversion of mass into volume requires knowledge of the water density, which can be estimated, measured directly or determined by other means. The error of measurement of the EUT is determined by comparing the volume recorded by the EUT and the volume collected in the tank. The density of water is, therefore, one of the major causes of measurement uncertainty in laboratory calibration of water meters using the gravimetric method. Water meter calibration facilities commonly use density formulations proposed by the International Standards Organisation (ISO) and the Organisation for International Legal Metrology (OIML). In Australia, additional guidance in water density determination is provided by the National Measurement Institute (NMI). In this study, testing was undertaken using ten positive displacement water meters arranged in series in the test rig to evaluate some of the common water density formulations used in Australia. The effect of these different formulations on the water meter error measurement was determined, as well as the effect on the measurement uncertainties. The results shows that the use of these different density formulations evaluated do not significantly affect the water meter error of measurement or the uncertainty of measurement. There was no apparent correlation between the water meter error and the meter position in the test rig. It was also determined that if the water density was adjusted only for temperature effects, a maximum of 0.05 and 0.15% drift in meter error and measurement uncertainty respectively, can be expected.
Publication Type: Journal Article
Source of Publication: Flow Measurement and Instrumentation, v.45, p. 188-197
Publisher: Elsevier Ltd
Place of Publication: United Kingdom
ISSN: 1873-6998
0955-5986
Fields of Research (FoR) 2008: 091504 Fluidisation and Fluid Mechanics
Fields of Research (FoR) 2020: 401299 Fluid mechanics and thermal engineering not elsewhere classified
Socio-Economic Objective (SEO) 2008: 960913 Water Allocation and Quantification
960912 Urban and Industrial Water Management
Socio-Economic Objective (SEO) 2020: 190211 Water policy (incl. water allocation)
180305 Ground water quantification, allocation and impact of depletion
180699 Terrestrial systems and management not elsewhere classified
Peer Reviewed: Yes
HERDC Category Description: C1 Refereed Article in a Scholarly Journal
Appears in Collections:Journal Article
School of Environmental and Rural Science

Files in This Item:
4 files
File Description SizeFormat 
Show full item record

SCOPUSTM   
Citations

9
checked on Nov 30, 2024

Page view(s)

960
checked on Mar 9, 2023

Download(s)

2
checked on Mar 9, 2023
Google Media

Google ScholarTM

Check

Altmetric


Items in Research UNE are protected by copyright, with all rights reserved, unless otherwise indicated.