Full-Resolution Lung Nodule Localization From Chest X-Ray Images Using Residual Encoder-Decoder Networks

Title
Full-Resolution Lung Nodule Localization From Chest X-Ray Images Using Residual Encoder-Decoder Networks
Publication Date
2023-12-15
Author(s)
Horry, Michael J
Chakraborty, Subrata
( author )
OrcID: https://orcid.org/0000-0002-0102-5424
Email: schakra3@une.edu.au
UNE Id une-id:schakra3
Pradhan, Biswajeet
Paul, Manoranjan
Zhu, Jing
Barua, Prabal Datta
Mir, Hasan Saeed
Chen, Fang
Zhou, Jianlong
Acharya, U Rajendra
Type of document
Journal Article
Language
en
Entity Type
Publication
Publisher
Institute of Electrical and Electronics Engineers
Place of publication
United States of America
DOI
10.1109/ACCESS.2023.3343451
UNE publication id
une:1959.11/59342
Abstract

Lung cancer is the leading cause of cancer death, and early diagnosis is associated with a positive prognosis. Chest X-ray (CXR) provides an inexpensive imaging mode for lung cancer diagnosis. Computer vision algorithms have previously been proposed to assist human radiologists in this task; however, leading studies use down-sampled images and computationally expensive methods with unproven generalization. In contrast, this study localizes lung nodules from CXR images using efficient encoder-decoder neural networks that have been crafted to process full resolution input images, thereby avoiding signal loss resulting from down-sampling. Encoder-decoder networks are trained and tested using the Japanese Society of Radiological Technology dataset. The networks are used to localize lung nodules from an independent CXR dataset. These experiments allow for the determination of the optimal network depth, image resolution, and pre-processing pipeline for generalized lung nodule localization. We find that more subtle nodules are detected in earlier training epochs. Therefore, we propose a novel self-ensemble model from three consecutive epochs centered on the validation optimum. This ensemble achieved a sensitivity of 85% in 10-fold internal testing with false positives of 8 per image. A sensitivity of 81% is achieved at a false positive rate of 6 following morphological false positive reduction. This result is comparable to more computationally complex systems, but with a sub-second inference time that is faster than other methods presented in the literature. The proposed algorithm achieved excellent generalization results against a challenging external dataset with a sensitivity of 77% at a false positive rate of 7.6.

Link
Citation
IEEE Access, v.11, p. 143016-143036
ISSN
2169-3536
Start page
143016
End page
143036
Rights
Attribution-NonCommercial-NoDerivatives 4.0 International

Files:

NameSizeformatDescriptionLink
openpublished/FullResolutionChakraBarua2023ConferencePaper.pdf 4413.328 KB application/pdf Conference Paper View document